PremiumTower™ S2 208V
Sustainable resilience at its best
PREMIUMTOWER S2 208V
PremiumTower™ S2 208V is designed for businesses of all sizes, offering a power range from 5 to 40 kW. Integrated internal batteries reduce footprint, remove the need for external battery frames, and simplify installation for a cost-efficient setup without compromising performance.
With three independent power converters, PremiumTower™ S2 208V maintains power supply continuity even if a component fails, helping minimise the risk of downtime and data loss. With an efficiency of up to 97.1% in double conversion (VFI), it reduces energy use and heat output, lowering operating costs and contributing to a more sustainable power infrastructure.
High efficiency: 97.1%
Increased nominal rating (kW = KVA)
15+ years life on replaceable components
Smart-predictive fans
Backfeed protection (standard)
500% higher charging current than typical standalone UPS
Up to 40kW with internal batteries
PREMIUMTOWER S2 208V
Benefits and features
- UPS supports dual or single AC input feeds to increase power availability further
- Wide compatibility with different battery technologies, including Lead-acid, Lithium, NiCd, Gel, Flywheels, and more
- Flexible number of battery blocks (14 to 28), allowing system designers to optimise cost versus autonomy time
- Short-circuit capability of up to 3 times nominal current (3 x In) for fast protection clearing
- Continuous operation during unexpected load demands of up to 120% of UPS nominal capacity
- Up to 97.1% efficiency in VFI with optimised performance at partial loads
- Lateral full access for service and maintenance
- Reduced repair time and costs with direct component access and plug-and-play boards
- Smart-predictive fans with closed-loop control detect wear and alert operators at the right time for replacement
- Integrated autonomy of up to 240 battery blocks (5 to 40 kW) to reduce footprint
- Matching battery cabinets available for extended runtimes
- Flexible DC range for optimised system design
- Up to 5 times more charging current than a typical standalone UPS, eliminating the need for external chargers
- Compact footprint: only 0.29 m²for 5/10/15/20 kW with 120 internal batteries or for 30/40kW with external batteries and only 0.44 m² from 10 to 80 kW systems with up to 240 internal batteries
- Unity power factor (kVA = kW), eliminating the need for system oversizing
- No replaceable components for 15+ years, reducing waste and lifecycle costs
PREMIUMTOWER S2 208V
Autonomy times
PremiumTower™ S2 208V features a powerful DC converter and industry-leading charging capability, ensuring rapid battery recharge. This makes it ideal for applications requiring extended autonomy and maximum availability.
Refer to the brochure for a comprehensive overview of autonomy times.
PREMIUMTOWER S2 208V
Available models